Suppose there is some fault like short circuit so protecting relay will sense the fault and gives the trip. Feb 25, 2017 breaking capacity is defined as the maximum short circuit current that a breaker can interrupt without damage to it. Jul 07, 20 making capacity means currentcapacity of the breaker in ka which it can handle during closing even if line has short circuit fault. Whats the breaking and making capacity of a circuit breaker. Making current of a circuit breaker is the peak value of maximum current loop during subtransient condition including dc component when breaker closes. Breaking capacity of circuit breaker wiki product faqs. To find making capacity multiply symmetrical breaking current by root 2 to convert from r. Circuit breaker ratings breaking capacity making capacity. Making and breaking capacity diffrent from each other. For the release pr1, it is also possible to select neutral protection at 150% and 200% of the rated current of the phases, if compatible with the setting of the current transformers. Typically for mcb the maximum icu will be 6ka to 10 ka for mccb icu may be 200kamps. In iec it is considered to be ais if the capacitance of the liaison between circuit breaker and a line is less than 1. Generally circuit breaker rating are defined in terms of breaking and making capacity.
These circuit breakers employ the high resistance interruption principle. Making capacity of a circuit breaker is the maximum current which the breaker can conduct at the instant of closing. A circuit breaker may be called upon to operate under all conditions. The capacity of a breaker to make current depends upon its ability to. Unless there is a guarantee that no fault will ever occur at less than 4 feet 10 inches from the load terminals of the circuit breaker, this circuit breaker. This is an important concept that underscores the principles of protection and. What is the rated shortcircuit making capacity icm. The breaking capacity of a cb is expressed as v3 vi 106 mva a. There is always a possibility of closing or making the circuit under shortcircuit conditions. For ns 100 n, 100a mccb at 440v, short circuit breaking capacity icu 35 ka then, icm 2. The question was actually how important is circuit breaker breaking capacity. This means that they can handle a fault of 1, protective device scpd. Depending on the above duties circuit breaker has three ratings breaking capacity, making capacity and short time capacity.
Its enclosure and components adopts high fireretarding and shockresistance plastic of long durability. The value of short circuit breaking current is expressed in rms during short circuit, the cb is not only subjected to thermal. Technical data sheet medium voltage distribution lf circuit. What is the difference between making capacity and breaking.
A circuit breaker s breaking capacity describes the maximum current that it can carry. How to calculate the value of the breaking capacity. What is the making capacity of the circuit breaker. Circuit breaker breaking capacity calculator with formula. Schneider electric nt masterpact circuit breaker i think this post is going to be helpful to several of our readers. Jul 24, 2016 to understand this aspect making current and breaking current, first we should know what actually the making current and breaking current signifies in context with circuit breaker. If a fault current exceeds icu, the circuit breaker is not capable of interrupting it and the fault must be cleared by the main breaker, which has a higher breaking capacity by design. Hence short circuit breaking capacity or short circuit breaking current of circuit breaker is defined as maximum current can flow through the breaker from time of occurring short circuit to the time of clearing the short circuit without any permanent damage in the cb. The rated short circuit making capacity icm for compact ns moulded case circuit breaker is as per the table attached and is dependent on the short circuit breaking capacity icu. The prospective short circuit current which can occur under short circuit conditions should not exceed the rated breaking capacity.
Db123737 type tightening torque copper cables rigid flexible or with ferrule. What is the rating of icu ics icw icm of circuit breaker. Therefore, the agreed international standard of specifying breaking capacity is defined as the rated symmetrical breaking current at a rated voltage. The short circuit making capacity of circuit breaker is expressed in peak value not in rms value like breaking capacity. List of contents1 calculator2 formula3 calculations solved examples4 frequently asked questions calculator formula breaking capacity b.
The rated short circuit making capacity icm is a quantity that according to regulations must be in a certain ratio to the rated ultimate short circuit breaking capacity icu and that has to be guaranteed by the device manufacturer. Icu stands for ultimate breaking capacity is a short circuit breaking capacity from the r. Hence, making capacity is always more than breaking capacity. Every electrical equipment will have rating mentioned on it to avoid the damage of it. Calculation and comparison of circuit breaker parameters in. The main task of a circuit breaker is to interrupt fault currents and to. The rated shortcircuit making capacity icm for compact ns moulded case circuit breaker is as per the table attached and is dependent on the shortcircuit breaking capacity icu. Also, cb is designed for considering its application as generator cb because fault level is highest at generator terminal and therefore higher making and breaking capacity is required for generator cb. The making capacity is considered to the peak value of the first cycle when there is an imaginary short circuit between the phases. This is the zone in which the thermal protection for thermomagnetic releases and protection l for electronic releases are normally called on to intervene. Rated short circuit making capacity icm the rated short circuit making capacity icm is a quantity that according to regulations must be in a certain ratio to the rated ultimate short circuit breaking capacity icu and that has to be guaranteed by the device manufacturer. Why making current of circuit breaker is more than breaking. What is ultimate breaking capacity of a circuit breaker. Both a and r are true and r is the correct explanation of a b.
It is current that a circuit breaker is capable of breaking at a given recovery voltage under specified conditions. Circuit breaker ratings a primer for protection engineers. Breaking capacity or interrupting rating is the current that a fuse, circuit breaker, or other. In comparison to making capacity of a circuit breaker its breaking capacity is normally higher. Shortcircuit switching making breaking capacity definition of switching capacity the switching capacity is the r. This 22,000a with short circuit power factor of 20% interrupting rated circuit breaker has an interrupting capacity of 9900a at a short circuit power factor of 88%. Residual current circuit breaker, fault making and breaking capacity on the order of 1 ka. Miniature circuit breaker breaking capacity abb datasheet. Rating of circuit breaker short circuit breaking making. Suppose there is some fault like short circuit so protecting relay will sense the fault and gives the. Miniature circuit breaker breaking capacity datasheet. The earlier practice was to express the rated breaking capacity in. How to calculate the value of the breaking capacity sciencing.
Breaking capacity of the circuit breaker refers to the maximum current that the. This explains standard ratings of circuit breaker and making capacity and breaking capacity of circuit breakers. Jul 04, 20 ics is the maximum perspective fault current which the circuit breaker can clear and still remain serviceable. Table is extracted from iec 609472 document for ns 100 n, 100a mccb at 440v, shortcircuit breaking capacity icu 35 ka then, icm 2. What is the shortcircuit switching making breaking. Ics means rated service breaking capacity or service short circuit breaking capacity. Both the shortcircuit making capacity as well as the shortcircuit breaking capacity of circuit breakers must be larger than or equal to the prospective shortcircuit current at the place of installation if this is not the case, then a suitable backup protection for example a fuse should be provided to ensure the required switching capacity of the device combination.
Lf circuit breaker technical data sheet sf6 breaking up to 17. Breaking capacity or interrupting rating is the current that a fuse, circuit breaker, or other electrical apparatus is able to interrupt without being destroyed or causing an electric arc with unacceptable duration. Ultimate breaking capacity icu the maximum current the circuit breaker can interrupt, although it will suffer permanent damage if the value exceeds ics. What is meaning of breaking capacity and making capacity of breaker. Depending on the above duties circuit breaker has three ratings braking capacity, making capacity and short time capacity. Difference between making and breaking capacity of circuit breaker 05192007 9.
How important is circuit breaker breaking capacity. Jun 03, 2017 breaking capacity or interrupting rating is the current that a fuse, circuit breaker, or other electrical apparatus is able to interrupt without being destroyed or causing an electric arc with unacceptable duration. Theoretically at the instant of fault occurrence in a system, the fault current can rise to twice of its symmetrical fault level. Difference between making and breaking capacity of circuit. Circuit breakers breaking capacity is the rated rms value of current that a cb can break at the rated voltage. When specified as a percentage of ics, the standard proposes ranges of 25%, 50%, 75%. The arc is rapidly lengthened by means of the arc runners and arc chutes and the. Circuit breaker is of gis or dead tank type depending on the capacitance of the liaison to overhead lines, it is considered as a gis or ais circuit breaker. The standard does allow some minor welding of the contacts to take place, so after a large fault it would still be necessary to inspect the breaker. While the iec low voltage circuit breaker standard iec 609472, low voltage switchgear and controlgear part 2. However, major duties are imposed on the circuit breaker when there is a fault on the system in which it is connected. Circuit breakers has been around for many years now, its surprising how often fault ratings are misunderstood.
The general procedure for the selection of correctly rated circuit breaker follows the following scheme of seven major questions you should answer. Below the value, which engineers also call the interrupting rating, the circuit breaker can safely short the circuit. So it is designed basically assuming that there is a short circuit and breaker contact should withstand this much current in this fault condition during closing. What is the rated shortcircuit making capacity icm value. What is the difference between making capacity and.
Rating of circuit breaker short circuit breaking making current. Both a and r are true and r is not the explanation of a c. Icu is nothing but unlimited break capacity of the circuit breaker which means the circuit breaker can break the maximum fault current without damage. This gives the rccb and the rest of the, features, offering cost effective solutions in different applications. Both the shortcircuit making capacity as well as the shortcircuit breaking capacity of circuit breakers must be larger than or equal to the prospective short circuit.